Arc fault trickle lights LEDs


By Chuck, Section Light
Posted on Wed Mar 04, 2009 at 04:51:37 PM MST
Interesting side effect of arc-fault breaker

I'm just finishing up my house, getting ready for the final inspection. When I did the electrical I was required by code to install and arc fault breaker for the bedroom circuits. Newer houses are soon to require arc-fault circuits everywhere, at least in my county. Not a big deal other than a bit more expensive. So far universal motors haven't popped the breaker.

Then the other day I picked up some LED lights and was eager to make use of 1.3 watt luminescence. I put them in light sockets on the bedroom circuit. They work fine, although they aren't as bright as an equivalently rated (40 watt equivalent) CFL.

I discovered that I now have night lights. Even when turned off they glow softly. I'm not sure how exactly, since the circuit is not complete. If I pop the breaker, the light goes out completely. If I put the LED bulbs on a different, non arc-fault circuit, there is no light produced. As soon as I put them back on the arc-fault circuit, they glow. When turned on they put out the normal amount of light.

I'm going to assume this has something to do with how arc-fault breakers operate, but haven't found a good explanation anywhere. Does anyone know the details of how arc-fault breakers work ?

Arc fault trickle lights LEDs | 18 comments (18 topical)

Re: Arc fault trickle lights LEDs (3.00 / 0) (#1)
by ghurd on Wed Mar 04, 2009 at 03:32:48 PM MST

LEDs will glow fairly well with 1/100th of a ma.

US and UK are not the same.
Need to know where you are to begin guessing at the solution.

I am guessing it is UK, because I do not know the term "arc-fault breakers"



Re: Arc fault trickle lights LEDs (3.00 / 0) (#2)
by paulb662000 on Wed Mar 04, 2009 at 03:57:22 PM MST

US electrical code now calls for these. A note of the code item and a short description is here. http://arcfaultcircuitbreaker.com/

Looking at the section "HOW THE AFCI WORKS" partway down this page http://arcfaultcircuitbreaker.com/afci_fact_sheet.htm I wonder if the sensing circuit could be feeding the tiny amount of power needed.

Paul

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#5)
by Chuck on Wed Mar 04, 2009 at 04:25:52 PM MST

Hi Paul,
Yes, right on all counts. Unfortunately the how it works section is very short on specifics.

I surmised that there must be a trickle of current being utilized by the sensor, but I still don't know how a current, no matter how small, can be flowing in a circuit that has the switch turned off. Both hot and neutral connect to the breaker, but the other end (switch) is open, no contact, thus no current flow. The sensor circuit can only flow within the breaker. Or so my logic leads and dumps me. So I'm still confused.

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#7)
by Madscientist267 on Wed Mar 04, 2009 at 06:56:00 PM MST

Your LED nightlights are probably not truly 'off' but being turned off by a transistor/SCR/triac.

If there is sufficient noise produced by the sensing circuit in the AFCI, there may be transients that are sufficient to pass through. One of those cable sniffers may be able to provide some insight, if straight out ripping one apart doesn't reveal the answer. :)

If the LED lights have a CdS cell in them to detect light, it is highly possible that this is how they are set up, and so will not light up when plugged into a regular outlet. Small power supplies inside such things are notorious for using capacitive-transformerless designs, which are rather 'sensitive' to high frequency switching like what may be happening inside the AFCI.

Not 100% on this, but it's likely.

Steve


[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#3)
by Chuck on Wed Mar 04, 2009 at 04:05:12 PM MST

Nope, USA. I hadn't heard about them either until a friend who's an electrician clued me into the code change.

[ Parent ]


Re: Arc fault trickle lights LEDs (3.00 / 0) (#4)
by ghurd on Wed Mar 04, 2009 at 04:11:07 PM MST

"GFCI"?
Yes, they leak.
G-

[ Parent ]


Re: Arc fault trickle lights LEDs (3.00 / 0) (#6)
by Chuck on Wed Mar 04, 2009 at 04:32:09 PM MST

Ghurd,
Arc-Fault are not GFCIs. They are about twice as expensive. AFCIs deal with normal overloads and also arcing or sparking. Somehow they are supposed to allow brushed motors to function, but pop when sparks happen in the house wiring, like a loose connection might cause. Both types can be touchy. GFCIs certainly can be when running several on the same circuit.

[ Parent ]


Re: Arc fault trickle lights LEDs (3.00 / 0) (#8)
by dnix71 on Wed Mar 04, 2009 at 08:26:35 PM MST

Arrgh. Will these things trip if you are a sloppy when arc welding? GFCI's can be touchy enough.

[ Parent ]


Re: Arc fault trickle lights LEDs (3.00 / 0) (#13)
by paulb662000 on Thu Mar 05, 2009 at 03:25:04 PM MST

The code calls for the arc faults to be on indoor living space circuits. Garage, outdoor, and circuits near water (kitchen, bath, laundry) are GFCI. So, as long as you are not welding inside you should be OK. I have talked to a number of electricians who have said their number 1 call back on new construction is arc fault breakers tripped by brushed motors in vaccum cleaners.

Paul

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#12)
by bj on Thu Mar 05, 2009 at 02:12:07 PM MST

   Ghurd just for info--they became code in Alberta in 99 when I was building this house.  Don't know much about them except at that time
they were about triple the cost.  Less now I think.  Just tripped mine,
and could not read anything with meter on MV, except usual noise on this
setting.
   bj

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#9)
by cardamon on Wed Mar 04, 2009 at 08:58:26 PM MST

I hate arc fault breakers.  As an electrician, I am aware of the extensive debates on these things.  Personally I feel they were rushed into the code before they were proven to function or provide sufficient extra protection to be worth the cost.  I think pre-twisting connections before wire-nutting and not using the back stabs on switches and receptacles would provide far more safety that an AFCI.  Sorry this doesn't address the OP, rant over.



Re: Arc fault trickle lights LEDs (3.00 / 0) (#11)
by halfcrazy on Thu Mar 05, 2009 at 04:16:22 AM MST

Cardamon I have to agree 100% they wherent ready for prime time

[ Parent ]


Re: Arc fault trickle lights LEDs (3.00 / 0) (#14)
by Madscientist267 on Thu Mar 05, 2009 at 07:25:34 PM MST

To add to this;

<begin rant>

I think if they got rid of 'back-stab' connections altogether, there's 99% (ish?) of the problem to start with.

I moved into new construction, and can't tell you the number of outlets and switches I have had to go behind 'the professional' on, and fix the crap that he built my house with. In fact, if the wiring problems keep up, I'm going to look into going about reparations. Seeing what I am seeing, it reminds me of Quest plumbing. Why fix something that is inherently broken with some more broken crap?

I personally would be willing to pay an electrician for all the extra time it would take to turn screws like the old days and do the job right the first time, than to deal with the BS that comes from some short cut that some idiot developed somewhere. GFCI I agree with. Protect humans from humans. AFCI? Thats crap. If something isn't safe, it shouldn't be in the circuit to start with. PERIOD.

</end rant>

Steve

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#15)
by Madscientist267 on Thu Mar 05, 2009 at 08:26:03 PM MST

Oh yeah, and did I mention?

Not ONCE did an AFCI TRIP due to anything. Not from lack of valid circumstance, I promise. :(

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#10)
by Opera House on Thu Mar 05, 2009 at 02:47:53 AM MST

It possibly has nothing to do with the breaker but with the wiring.  If you temporarily replaced that breaker with a standard one it will likely still glow.  A long parallel line going to the switch from capacitance or wiring leakage.  I remember suggesting using common house cable for a resistive sense application and it was pointed to a wire to wire resistance.  Older mercury disk switches also can leak with age as the glass begins to plate with mercury.  



Re: Arc fault trickle lights LEDs (3.00 / 0) (#16)
by Flux on Fri Mar 06, 2009 at 06:53:27 AM MST

Leds need so little energy to make them glow that many devices with any capacitive paths will do it. In this age with filters and capacitors everywhere I am not surprised that things glow a bit.

With all the switching power supplies that seem to be coming on line to replace transformers I think we shall have a lot of strange phenomena to explain.

Flux

[ Parent ]



Re: Arc fault trickle lights LEDs (3.00 / 0) (#17)
by Chuck on Fri Mar 06, 2009 at 09:13:45 AM MST

Thanks everyone for the comments. At this point I'm fairly happy with a mix of LED and CFLs. With arc fault on just two circuits I only have a few places where the LEDs glow softly while turned off. If they are truly glowing only on the noise of the arc fault breakers, which have to be there anyway, I'll accept the night lights. It does seem odd that the breakers would so noisy and/or amazing that LEDs are so sensitive. It reminds me of the old photos of people holding florescent tubes under power lines and watching them glow.



Re: Arc fault trickle lights LEDs (3.00 / 0) (#18)
by Gordy on Sat Mar 07, 2009 at 12:38:47 AM MST

Chuck,

I noticed the same thing with several strings of LED Christmas lights. Though they are on a regular circuit breaker. I assumed something was wrong with the switched cord I used. It looks like an extension cord but has a switch on one end and combination male/female plug on the other end.

It's interesting that the blue and green are the brightest, red barely glows, and the yellow and orange no glow at all. Although they don't glow bright enough to see where your going.

Grud,

The arc fault breakers that I have (in MN, USA). Look like a regular CB except they have a yellow test button and if you pull the panel cover they have a white wire coming from inside that is hooked to the ground / neutral bus.

Gordy

[ Parent ]



Arc fault trickle lights LEDs | 18 comments (18 topical)
Display: Sort:
Menu
· create account
· How to use the board
· FAQs
· search the board
· Google search the board

Login
Make a new account
Username:
Password:

Total Views
  130 Scoop users have viewed this posting.

Related Links
· Also by Chuck

Powered by Scoop
You must be a registered user to post here. It's easy and free, and the link is on the upper right side of your page.
All trademarks and copyrights on this page are owned by their respective companies. Postings are owned by the poster, but may be deleted or moved at the ADMIN's sole discretion. The Rest © 2009 Forcefield.
You can Email the board ADMIN here. PLEASE include the username you signed up with!